ecowitt_iot — DEPRECATED

This integration is no longer maintained. Ecowitt now publishes an official Home Assistant integration that covers the same devices over the same local API, and is actively developed:

https://github.com/Ecowitt/ha-ecowitt-iot

Release 1.1.0 is the final release of ecowitt_iot. It contains one safety fix (see below), the long-promised timer services, and a Repairs notice pointing you here. No further changes will be made and new issues will not be worked on.

The repository will be archived three months after the 1.1.0 release date (the exact date is in the release notes). Archiving makes it read-only; the 1.1.0 release stays installable through HACS, but nothing will be updated and issues cannot be opened.

Thank you to everyone who tested, reported bugs and sent pull requests, and for your patience while issues went unanswered for most of a year. This started because the core ecowitt integration is push-based and could not drive the WFC01 WittFlow water timer or the AC1100 WittSwitch plug; the vendor has now filled that gap properly.

Migrating to the official integration

  1. In HACS, add https://github.com/Ecowitt/ha-ecowitt-iot as a custom repository (category Integration), download it and restart Home Assistant.
  2. Add Ecowitt Official Integration from Settings → Devices & services, pointing it at the same gateway IP you used here. Both integrations can run side by side during the changeover.
  3. Confirm your valves and plugs appear and that switching them works.
  4. Update automations, scripts, dashboards and helpers (in particular any utility_meter) to the new entity IDs. Entity IDs do not carry over: this integration keyed entities by device ID, the official one keys them by the device nickname.
  5. Remove the Ecowitt IoT - unofficial, Bwooce (deprecated) integration, then remove the repository from HACS.

What the official integration does differently

Feature ecowitt_iot (this repo) Official
WFC01 / AC1100 Yes Yes
WFC02 No Yes
Valve / plug switch Yes Yes, with optimistic state
Flow rate, water total, power, voltage, energy Yes Yes
Water temperature unit °C or °F (selectable) °F label, converted by HA
Warning-bit binary sensors (leak, no water, temp, battery) Yes No
Device-side timed run / run by volume (services) Yes No
Weather-station sensors on the same gateway No Yes
Poll interval Fixed 30 s Configurable, default 10 s

If you relied on the warning-bit binary sensors or the timer services, raise those as feature requests on the official repository; the data and commands are in the local API and in the wittiot library the official integration already uses (it supports a run duration internally but does not expose it).

1.1.0 — final release

  • Fix: a bare 200 OK from the gateway (command accepted, no reading yet) was turned into a complete set of fabricated zero readings. water_total: 0.00 is a valid value for a total_increasing sensor, so the next real reading looked like a meter rollover and utility_meter helpers booked the whole lifetime counter as consumption. The coordinator now keeps the last good reading or leaves the device unavailable. Reported with a precise diagnosis in #19.
  • Added a Repairs issue announcing the deprecation.
  • Added async_unload_entry so the integration can be reloaded and removed cleanly.
  • New: the set_valve_timer and set_power_timer services that services.yaml has advertised since 0.1.0 now exist, plus run_by_volume for the WFC01 (#3). All three run the timer on the gateway (quick_run with always_on: 0), so the output stops even if Home Assistant goes away mid-cycle.
  • The switch now reports water_status / ac_status only. On a real WFC01 water_running lags the valve state by about a second after quick_stop, which left the switch showing on for a full poll.
  • The config flow's temperature unit option is unchanged. Ecowitt's API document says water_temp is °F, but a GW2000 with firmware 3.3.2 reports Sydney mains water as 18.8–20.2, which is plainly °C. If your reading looks wrong, change the unit in the integration options (#14).
  • run_by_volume sends tenths of a litre to the gateway (the API document's "volume (L)" is wrong), capped at 1000 L per call.
  • Merged local brand assets (#21).

Reference

The local HTTP API this integration used is Ecowitt's "Local IoT API" document (get_iot_device_list and parse_quick_cmd_iot with the read_device, quick_run and quick_stop commands); the official integration's wittiot library implements the same calls.

This project is licensed under the terms in LICENSE.