Uplinks
Change downlink period
By making this a large value, this meets the requirement to stop downlinking completely
No-op
Downlinks
ChipSats shall not downlink at the same time. One ChipSat will have an initial delay to make the ChipSats offset.
ChipSats shall stop downlinking if they have not received an uplink in over 24 hours. This requirement is met by using an alive time counter which is NOT stored in EEPROM. If alive time exceeds 24 hours, downlinking is disabled.
Downlinks are always the same length. If a sensor fails, those sensor values are 0.