Is it possible to adjust the HCOF and RHS coefficients of an existing boundary condition package? I've tried this using set_advanced_var at the start of the outer iteration loop, but when calling solve() the coefficients are overwritten by the CF & FC subroutines (see also #30). Is there a way to prevent the solve() procedure from overwriting the user-defined HCOF and RHS values?

I'm basically trying to switch some GHB's from a third-type boundary condition to a constant-flux based on a maximum-allowed flow rate by adjusting the matrix coefficients (so setting HCOF to zero and setting RHS to the maximum flux). Alternatively, I can follow the approach of the custom ET package as shown in the MODFLOW-API paper, but that involves setting up a 'new' package instead of adjusting the behaviour of an existing one.